1. After the Shotcrete Machine shuts down, the spray gun should be inverted to prevent water from flowing into the feeding pipe.
2. After the Shotcrete Machine shuts down, the air ducts and water pipes should be neatly placed, and the shotcrete machine and surrounding areas should be cleaned to deal with rebound.
3. If any blockage or air stoppage is found during the shotcrete machine spraying process, the machine should be immediately stopped and the gun head should be inverted.
4. When dealing with pipe blockage, it is strictly prohibited to stand in front of the shotcrete machine muzzle to prevent sudden spraying or pipeline jumping from injuring people.
5. Each shift should clean the rubber sealing plate and check the wear of the Shotcrete Machine.
6. The Shotcrete Machine steel lining plate must be inspected once a week, and if there are deep scratches, it should be reground.
The above is an introduction to "How to operate Shotcrete Machine and what to pay attention to", hoping to be helpful to you.